The Lisun developed the HFP-800+RB-3 system to do equivalent test between fluorescent lamp and LED tube
Sept. 30, 2015
Comparing with traditional fluorescent lamp, the LED tube have high light effects, low power consume, long life time and stable luminous efficiency advantages etc. At the same time, for the LED tube performance testing is became more simple, in recent years more and more customers has chosen the LED tube to replace fluorescent lamp.
The IEC62776 standard from chapter 1 to chapter 3.2 are mentioned the LED tube can replace the double-capped fluorescent and how to use G5 and G13 lamp holder fluorescent lamp turn to LED tube, this kind of equivalent replacement needn't LED tube to do any change. At the same time, this standard also mentioned the IEC60081 double-capped fluorescent lamp performance test and LED tube suitable replace fluorescent lamp with integrated magnetic ballasts. How to do equivalent test between LED tube and fluorescent lamp, there will be use a high frequency power supply and high frequency adjustable reference ballast. As we knew the fluorescent lamp is consist of fluorescent capillary, electrical ballast and fixture. The testing process is connect RB-3 with double-capped of fluorescent capillary, also we need connect HFP-800 high frequency power with double-capped of fluorescent capillary, some of fluorescent capillary need to do preheating process according to IEC standard's requirement, as below picture. At the same time, the relevant parameters need set up according to IEC standard’s requirement.
The RB-3 is application with no sense of resistance ballast which is special designed for select reference light(fluorescent capillary), the characteristics of reference ballast have constant voltage and current ratio based on rated frequency, and it couldn't have any affected by voltage, temperature and ambient changes.
The HFP-800 provide high frequency reference ballast with pure and high frequency power supply. The HFP-800+RB-3 system not only can to do T5/T8 fluorescent lamp test, but also can to do LED tube equivalent test.
For the equivalent test between fluorescent lamp and LED tube, actually, it's take away the fluorescent capillary and connect LED tube(included driver) with EB, it's have necessary to explain the working principle of EB and driver: the EB is AC to AC model, when turn on the fluorescent lamp, there have a AC model high voltage to electric shock fluorescent capillary for lighting lamp, then the EB will output constant AC voltage to maintain the fluorescent lamp is always lighting on; the LED driver is AC to DC model, there have a DC power to lighting on singled LED or LED luminaires. So there use a LED tube(included driver) connect with EB which also keep AC to AC model, the equivalent test have three purposes: One is lighting on LED tube; Second is see whether the power consume of LED tube is lower than fluorescent lamp or not; third is light effect of LED tube is higher than fluorescent lamp(this will be judge by spectrometer & integrating sphere system). If need use best fair way to assess these three purpose, the EB is important, we can't use any of EB to do this kind of equivalent test, this EB must be mentioned or recommend by IEC or other standards, to solve this issue, Shanghai Lisun Electronic office developed HFP-800 High Frequency Power Supply and RB-3 High Frequency Adjustable Reference Ballast, both device are fully meet IEC60081 IEC60901 and ANSI C78.81 & C82.11standards.
The IEC62776 standard from chapter 1 to chapter 3.2 are mentioned the LED tube can replace the double-capped fluorescent and how to use G5 and G13 lamp holder fluorescent lamp turn to LED tube, this kind of equivalent replacement needn't LED tube to do any change. At the same time, this standard also mentioned the IEC60081 double-capped fluorescent lamp performance test and LED tube suitable replace fluorescent lamp with integrated magnetic ballasts. How to do equivalent test between LED tube and fluorescent lamp, there will be use a high frequency power supply and high frequency adjustable reference ballast. As we knew the fluorescent lamp is consist of fluorescent capillary, electrical ballast and fixture. The testing process is connect RB-3 with double-capped of fluorescent capillary, also we need connect HFP-800 high frequency power with double-capped of fluorescent capillary, some of fluorescent capillary need to do preheating process according to IEC standard's requirement, as below picture. At the same time, the relevant parameters need set up according to IEC standard’s requirement.
The RB-3 is application with no sense of resistance ballast which is special designed for select reference light(fluorescent capillary), the characteristics of reference ballast have constant voltage and current ratio based on rated frequency, and it couldn't have any affected by voltage, temperature and ambient changes.
The HFP-800 provide high frequency reference ballast with pure and high frequency power supply. The HFP-800+RB-3 system not only can to do T5/T8 fluorescent lamp test, but also can to do LED tube equivalent test.
For the equivalent test between fluorescent lamp and LED tube, actually, it's take away the fluorescent capillary and connect LED tube(included driver) with EB, it's have necessary to explain the working principle of EB and driver: the EB is AC to AC model, when turn on the fluorescent lamp, there have a AC model high voltage to electric shock fluorescent capillary for lighting lamp, then the EB will output constant AC voltage to maintain the fluorescent lamp is always lighting on; the LED driver is AC to DC model, there have a DC power to lighting on singled LED or LED luminaires. So there use a LED tube(included driver) connect with EB which also keep AC to AC model, the equivalent test have three purposes: One is lighting on LED tube; Second is see whether the power consume of LED tube is lower than fluorescent lamp or not; third is light effect of LED tube is higher than fluorescent lamp(this will be judge by spectrometer & integrating sphere system). If need use best fair way to assess these three purpose, the EB is important, we can't use any of EB to do this kind of equivalent test, this EB must be mentioned or recommend by IEC or other standards, to solve this issue, Shanghai Lisun Electronic office developed HFP-800 High Frequency Power Supply and RB-3 High Frequency Adjustable Reference Ballast, both device are fully meet IEC60081 IEC60901 and ANSI C78.81 & C82.11standards.